|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
INTEGRATED CONNECTOR MODULES 2 x n Multi-port Gigabit belStackTM BM02832 * Multi-port shielded RJ-45 connector with integrated Gigabit Ethernet magnetics Compatible with a variety of Gigabit Ethernet transceiver ICs and 10/100Base-TX transceiver ICs Operating temperature 0 to +70 C * Complies with IEEE 802.3ab standards and all Gigabit Ethernet specifications Integrated design conserves valuable board space Minimum interwinding breakdown voltage of 1500 Vrms Adaptable, modular design provides higher reliability * * * * * * Storage temperature -40 to +85 C ELECTRICAL SPECIFICATIONS AT 25 C Common to Differential Mode Rejection dB min 100KHz to 100MHz -35 Common to Common Mode Rejection dB min 100KHz to 100MHz -30 -33 + 20 log (f/100MHz) -33 + 20 log (f/100MHz) -33 + 20 log (f/100MHz) -33 + 20 log (f/100MHz) -33 + 20 log (f/100MHz) -33 + 20 log (f/100MHz) 1500 Insertion Loss dB max Part Number 0.1MHz to 100MHz 0833-2X4R-33 -0.8 100MHz to 125MHz -1.2 Return Loss dB min Crosstalk dB min Hipot Vrms min 0.5MHz to 40MHz -18 40MHz to 100MHz -12 + 20 log (f/80 MHz) -12 + 20 log (f/80 MHz) -12 + 20 log (f/80 MHz) -12 + 20 log (f/80 MHz) -12 + 20 log (f/80 MHz) -12 + 20 log (f/80 MHz) 0833-2X6R-33 -0.8 -1.2 -18 -35 -30 1500 0833-2X8R-33 -0.8 -1.2 -18 -35 -30 1500 0833-2X4R-54 -0.8 -1.2 -18 -35 -30 1500 0833-2X6R-54 -0.8 -1.2 -18 -35 -30 1500 0833-2X8R-54 -0.8 -1.2 -18 -35 -30 1500 Available Options * Various transformer turns ratios * Various high voltage capacitor values (c)2002 Bel Fuse Inc. Specifications subject to change without notice. 07.04 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com page 1 INTEGRATED CONNECTOR MODULES BM02832 2 x n Multi-port Gigabit belStackTM SCHEMATICS 1 0833-2X4R-33 0833-2X6R-33 0833-2X8R-33 1CT : 1CT RJ45 1 2 2 3 4 5 6 7 8 0.1F x4 75 x4 1000pF 2kV 1CT : 1CT 3 6 1CT : 1CT 4 5 1CT : 1CT 7 8 9 10 Shield 0833-2X4R-54 0833-2X6R-54 0833-2X8R-54 1 2 3 4 5 6 7 8 9 10 0.1F x4 1CT : 1CT RJ45 1 2 1CT : 1CT 3 6 1CT : 1CT 4 5 1CT : 1CT 7 8 75 x4 1000pF 2kV Shield (c)2002 Bel Fuse Inc. Specifications subject to change without notice. 07.04 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com page 2 INTEGRATED CONNECTOR MODULES 2 x n Multi-port Gigabit belStackTM MECHANICAL 0833-2X4R-33 0833-2X4R-54 BM02832 1.210 [30.73] max Outer Shield 1.004 [25.50] max 2.330 [59.18] Port 2 Port 8 Note * 0.150 [3.81] 0.125 [3.18] Housing 0.425 [10.80] 0.185 [4.70] Port 1 Port 7 Dimensions are in inches [millimeters]. Standard dimension tolerance is 0.010 [0.25] unless otherwise noted. Notes Plastic Housing Contacts Pins Solderability Metal Shield Thermoplastic, flammability rating UL 94V-0 50 micro-inch hard gold plating Tin-coated copper wire, DIA 0.018" [0.46] Per MIL Std. 202, Method 208 Nickel plated copper alloy Packing Quantity 20 pieces finished goods per tray 7 trays per carton box for a total of 140 pieces of finished goods *Jack cavity conforms to FCC rules and regulations, part 68, subpart F. 1.030 +0.010/-0.005 [26.16 +0.25/-0.13] 2.365 +0.010/-0.005 [60.07 +0.25/-0.13] Metal Panel 0.085 0.010 [2.16 0.25] 0.015 [0.38] Suggested Panel Opening PCB (c)2002 Bel Fuse Inc. Specifications subject to change without notice. 07.04 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com page 3 INTEGRATED CONNECTOR MODULES BM02832 2 x n Multi-port Gigabit belStackTM PAD LAYOUT 0833-2X4R-33 0833-2X4R-54 1.050 [26.67] 0.905 [22.99] 0.500 [12.70] 0.355 [9.02] o0.062 0.160 [4.06] [o1.57] 0.050 [1.27] 7 places 2.005 [50.93] 1.600 [40.64] 1.455 [36.96] o0.035 [o0.89] 80 places 0.450 [11.43] 0.680 0.610 [17.27] [15.49] 0.100 [2.54] 0.050 [1.27] 0.185 [4.70] 0.180 [4.57] 0.110 [2.79] o0.128 [o3.25] 2 places 0.290 [7.37] R0.030 [R0.76] 2.100 [53.34] Suggested PCB Pad Layout Component Side View Port 10 9 7 5 3 1 10 9 7 5 3 1 0.110 [2.79] Recommended PCB front edge cutout. The bottom shield ground tabs (front) should not be seated on the top of the PCB. 1 2 3 4 5 6 78 88 66 44 2.090 [53.09] Note The shaded area of bottom side of part may be covered by metal shield. 1.230 [31.24] 0.535 [13.59] 0.425 [10.80] 0.145 [3.68] 2.390 [60.71] (c)2002 Bel Fuse Inc. Specifications subject to change without notice. 07.04 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com page 4 INTEGRATED CONNECTOR MODULES BM02832 2 x n Multi-port Gigabit belStackTM MECHANICAL 0833-2X6R-33 0833-2X6R-54 1.210 [30.73] max Outer Shield 1.004 [25.50] max Port 2 3.430 [87.12] Port 12 0.150 [3.81] Note * 0.125 [3.18] Port 1 Housing 0.425 [10.80] 0.185 [4.70] Port 11 Dimensions are in inches [millimeters]. Standard dimension tolerance is 0.010 [0.25] unless otherwise noted. Notes Plastic Housing Contacts Pins Solderability Metal Shield Thermoplastic, flammability rating UL 94V-0 50 micro-inch hard gold plating Tin-coated copper wire, DIA 0.018" [0.46] Per MIL Std. 202, Method 208 Nickel plated copper alloy Packing Quantity 15 pieces finished goods per tray 7 trays per carton box for a total of 105 pieces of finished goods *Jack cavity conforms to FCC rules and regulations, part 68, subpart F. 1.030 +0.010/-0.005 [26.16 +0.25/-0.13] 3.465 +0.010/-0.005 [88.01 +0.25/-0.13] Metal Panel 0.085 0.010 [2.16 0.25] 0.015 [0.38] Suggested Panel Opening PCB (c)2002 Bel Fuse Inc. Specifications subject to change without notice. 07.04 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com page 5 INTEGRATED CONNECTOR MODULES BM02832 2 x n Multi-port Gigabit belStackTM 3.105 [78.87] 2.700 [68.58] 2.555 [64.90] 2.150 [54.61] 2.005 [50.93] 1.600 [40.64] 1.455 [36.96] 1.050 [26.67] PAD LAYOUT 0833-2X6R-33 0833-2X6R-54 0.905 [22.99] 0.500 [12.70] 0.355 [9.02] 0.160 [4.06] 0.050 [1.27] o0.062 [o1.57] 9 places 0.680 [17.27] 0.610 [15.49] o0.035 [o0.89] 120 places 0.450 [11.43] 0.100 [2.54] 0.050 [1.27] 0.185 [4.70] 0.180 [4.57] 0.110 [2.79] R0.030 [R0.76] o0.128 [o3.25] 2 places 0.290 [7.37] 0.110 [2.79] Recommended PCB front edge cutout. The bottom shield groundtabs (front) should not be seated on the top of the PCB. 3.200 [81.28] Suggested PCB Pad Layout Component SIde View 10 9 7 5 3 1 8 6 4 2 10 8 6 4 2 9 7 5 3 1 Port 1 2 34 5 6 78 9 10 11 12 3.190 [81.03] Note The shaded area of bottom side of part may be covered by metal shield. 1.230 [31.24] 0.535 [13.59] 0.425 [10.80] 0.145 [3.68] 3.490 [88.65] (c)2002 Bel Fuse Inc. Specifications subject to change without notice. 07.04 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com page 6 INTEGRATED CONNECTOR MODULES BM02832 2 x n Multi-port Gigabit belStackTM MECHANICAL 0833-2X8R-33 0833-2X8R-54 1.210 [30.73] max Outer Shield 1.004 [25.50] max 0.150 [3.81] 0.125 [3.18] Housing 0.425 [10.80] 0.185 [4.70] Dimensions are in inches [millimeters]. Standard dimension tolerance is 0.010 [0.25] unless otherwise noted. 4.530 [115.06] Port 2 Port 16 Note * Port 1 Port 15 Notes Plastic Housing Contacts Pins Solderability Metal Shield Thermoplastic, flammability rating UL 94V-0 50 micro-inch hard gold plating Tin-coated copper wire, DIA 0.018" [0.46] Per MIL Std. 202, Method 208 Nickel plated copper alloy Packing Quantity 10 pieces finished goods per tray 7 trays per carton box for a total of 70 pieces of finished goods *Jack cavity conforms to FCC rules and regulations, part 68, subpart F. 1.030 +0.010/-0.005 [26.16 +0.25/-0.13] 4.565 +0.010/-0.005 [115.95 +0.25/-0.13] Metal Panel 0.085 0.010 [2.16 0.25] 0.015 [0.38] Suggested Panel Opening PCB (c)2002 Bel Fuse Inc. Specifications subject to change without notice. 07.04 Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com page 7 INTEGRATED CONNECTOR MODULES BM02832 2 x n Multi-port Gigabit belStackTM 4.205 [106.81] 3.800 [96.52] 3.655 [92.84] 3.250 [82.55] 3.105 [78.87] 2.700 [68.58] 2.555 [64.90] 2.150 [54.61] 2.005 [50.93] 1.600 [40.64] 1.455 [36.96] PAD LAYOUT 0833-2X8R-33 0833-2X8R-54 o0.062 [o1.57] 11 places 0.680 [17.27] 0.610 [15.49] 1.050 [26.67] 0.905 [22.99] 0.500 [12.70] 0.355 [9.02] 0.160 [4.06] 0.050 [1.27] o0.035 [o0.89] 160 places 0.450 [11.43] 0.100 [2.54] 0.050 [1.27] 0.185 [4.70] 0.180 [4.57] 0.110 [2.79] 0.290 [7.37] R0.030 [R0.76] o0.128 [o3.25] 2 places 0.110 [2.79] 4.300 [109.22] Suggested PCB Pad Layout Component SIde View 10 9 7 5 3 1 8 6 4 2 10 8 6 4 2 9 7 5 3 1 Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Recommended PCB front edge cutout. The bottom shield groundtabs (front) should not be seated on the top of the PCB. 4.290 [108.97] Note The shaded area of bottom side of part may be covered by metal shield. 1.230 [31.24] 0.535 [13.59] 0.425 [10.80] 0.145 [3.68] 4.590 [116.59] (c)2002 Bel Fuse Inc. Specifications subject to change without notice. 07.04 CORPORATE Bel Fuse Inc. 206 Van Vorst Street Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com FAR EAST Bel Fuse Ltd. 8F / 8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 www.belfuse.com EUROPE Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Suite G7, Preston Lancashire, PR1 8UD, U.K. Tel 44-1772-556601 Fax 44-1772-888366 www.belfuse.com page 8 |
Price & Availability of 0833-2X8R-33 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |